Review measurement

2025-08-02 11:01

Ozone Zeolite GT ML (2019)

Accuracy

Is calculated by comparing each suspension point's length change to the main line's overall change after re-measurement. Deviations over 3.0mm from the average are considered noticeable and may distort the trim result.

Left riser

avg change:
1.25
std dev:
1.04
A5
dev:
+1.8
A6
dev:
+0.8
A7
dev:
-0.3
A8
dev:
-0.3
B5
dev:
-1.3
B6
dev:
+0.8
B7
dev:
-1.3
B8
dev:
-0.3
avg change:
5.13
std dev:
0.99
C5
dev:
+1.1
C6
dev:
+0.1
C7
dev:
-1.9
C8
dev:
-0.9
D5
dev:
+1.1
D6
dev:
+0.1
D7
dev:
+0.1
D8
dev:
+0.1

Right riser

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A15
nom:
6318
rdg:
6840
diff:
 -3
A16
nom:
6264
rdg:
6780
diff:
 -9
A17
nom:
6254
rdg:
6769
diff:
-10
B15
nom:
6342
rdg:
6866
diff:
 -1
B16
nom:
6313
rdg:
6833
diff:
 -5
B17
nom:
6298
rdg:
6811
diff:
-12

Right riser

A15
nom:
6318
rdg:
6840
diff:
 -3
A16
nom:
6264
rdg:
6778
diff:
-11
A17
nom:
6254
rdg:
6767
diff:
-12
B15
nom:
6342
rdg:
6861
diff:
 -6
B16
nom:
6313
rdg:
6828
diff:
-10
B17
nom:
6298
rdg:
6811
diff:
-12

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

This should be corrected.

Left riser

nom:
7638.75
rdg:
7631.88
diff:
-6.88
nom:
7637.00
rdg:
7640.50
diff:
3.50

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median (-6) of the deviations of all measurements from their nominal values.

No issues were found