Review measurement
2026-09-16 19:57
Ozone Lyght S (2024)
In-group deviations
Readings that are more than 10
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
A9
nom:
6449
rdg:
6311
diff:
-138
A10
nom:
6332
rdg:
6192
diff:
-140
A11
nom:
6267
rdg:
6135
diff:
-132
A12
nom:
6197
rdg:
6068
diff:
-129
A13
nom:
6191
rdg:
6057
diff:
-134
B12
nom:
6216
rdg:
6081
diff:
-135
B13
nom:
6217
rdg:
6085
diff:
-132
Right riser
A1a
nom:
6979
rdg:
6845
diff:
-134
A2a
nom:
6881
rdg:
6740
diff:
-141
A3a
nom:
6846
rdg:
6711
diff:
-135
A4a
nom:
6878
rdg:
6743
diff:
-135
A1b
nom:
6966
rdg:
6829
diff:
-137
A2b
nom:
6867
rdg:
6729
diff:
-138
A3b
nom:
6833
rdg:
6694
diff:
-139
A4b
nom:
6866
rdg:
6730
diff:
-136
A9
nom:
6449
rdg:
6310
diff:
-139
A10
nom:
6332
rdg:
6195
diff:
-137
A11
nom:
6267
rdg:
6139
diff:
-128
A12
nom:
6197
rdg:
6068
diff:
-129
A13
nom:
6191
rdg:
6066
diff:
-125
B12
nom:
6216
rdg:
6086
diff:
-130
B13
nom:
6217
rdg:
6084
diff:
-133
Trim
Groups arranged behind each other in flight direction having more than 10
No issues were found
Group deviations
Groups that are more than 20
The measurement baseline is the median (-137) of the deviations of all measurements from their nominal values.
No issues were found