Review measurement

2025-07-11 21:24

PHI Maestro Light 19 (2020)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

1B7
nom:
6386
rdg:
6944
diff:
+18
1B8
nom:
6281
rdg:
6843
diff:
+22
1B9
nom:
6295
rdg:
6855
diff:
+20
1B10
nom:
6166
rdg:
6723
diff:
+17
1B11
nom:
6096
rdg:
6651
diff:
+15
1B12
nom:
6097
rdg:
6646
diff:
 +9

Right riser

1B7
nom:
6386
rdg:
6944
diff:
+18
1B8
nom:
6281
rdg:
6842
diff:
+21
1B9
nom:
6295
rdg:
6858
diff:
+23
1B10
nom:
6166
rdg:
6727
diff:
+21
1B11
nom:
6096
rdg:
6655
diff:
+19
1B12
nom:
6097
rdg:
6650
diff:
+13

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

No issues were found

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found