Review measurement
2024-08-16 00:20
Triple Seven Rook 2 ML (2015)
In-group deviations
Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
a11
nom:
6216
rdg:
6771
diff:
-25
a12
nom:
6144
rdg:
6705
diff:
-19
a13
nom:
5981
rdg:
6534
diff:
-27
b11
nom:
6165
rdg:
6700
diff:
-45
b12
nom:
6102
rdg:
6647
diff:
-35
b13
nom:
5989
rdg:
6532
diff:
-37
c13
nom:
6137
rdg:
6679
diff:
-38
c14
nom:
6088
rdg:
6066
diff:
-602
c1
nom:
6938
rdg:
7475
diff:
-43
c2
nom:
6851
rdg:
7394
diff:
-37
c3
nom:
6799
rdg:
7349
diff:
-30
c4
nom:
6819
rdg:
7365
diff:
-34
d1
nom:
6979
rdg:
7508
diff:
-51
d2
nom:
6937
rdg:
7469
diff:
-48
c5
nom:
6821
rdg:
7362
diff:
-39
c6
nom:
6757
rdg:
7332
diff:
-5
c7
nom:
6722
rdg:
7772
diff:
+470
c8
nom:
6747
rdg:
7300
diff:
-27
d3
nom:
6861
rdg:
7397
diff:
-44
d4
nom:
6814
rdg:
7337
diff:
-57
c9
nom:
6647
rdg:
7188
diff:
-39
c10
nom:
6546
rdg:
7088
diff:
-38
c11
nom:
6460
rdg:
7003
diff:
-37
c12
nom:
6466
rdg:
7008
diff:
-38
d5
nom:
6717
rdg:
7247
diff:
-50
d6
nom:
6591
rdg:
7126
diff:
-45
Right riser
a7
nom:
6639
rdg:
7189
diff:
-30
a8
nom:
6562
rdg:
7117
diff:
-25
a9
nom:
6466
rdg:
7021
diff:
-25
a10
nom:
6462
rdg:
7011
diff:
-31
a11
nom:
6216
rdg:
6765
diff:
-31
a12
nom:
6144
rdg:
6698
diff:
-26
a13
nom:
5981
rdg:
6538
diff:
-23
b11
nom:
6165
rdg:
6721
diff:
-24
b12
nom:
6102
rdg:
6659
diff:
-23
b13
nom:
5989
rdg:
6543
diff:
-26
c13
nom:
6137
rdg:
6678
diff:
-39
c14
nom:
6088
rdg:
6069
diff:
-599
c1
nom:
6938
rdg:
7475
diff:
-43
c2
nom:
6851
rdg:
7394
diff:
-37
c3
nom:
6799
rdg:
7351
diff:
-28
c4
nom:
6819
rdg:
7356
diff:
-43
d1
nom:
6979
rdg:
7515
diff:
-44
d2
nom:
6937
rdg:
7463
diff:
-54
c5
nom:
6821
rdg:
7362
diff:
-39
c6
nom:
6757
rdg:
7331
diff:
-6
c7
nom:
6722
rdg:
7269
diff:
-33
c8
nom:
6747
rdg:
7295
diff:
-32
d3
nom:
6861
rdg:
7402
diff:
-39
d4
nom:
6814
rdg:
7344
diff:
-50
c9
nom:
6647
rdg:
7188
diff:
-39
c10
nom:
6546
rdg:
7088
diff:
-38
c11
nom:
6460
rdg:
7007
diff:
-33
c12
nom:
6466
rdg:
7009
diff:
-37
d5
nom:
6717
rdg:
7245
diff:
-52
d6
nom:
6591
rdg:
7119
diff:
-52
Trim
Groups arranged behind each other in flight direction having more than 10 mm deviation.
This should be corrected.
Left riser
nom:
7343.00
rdg:
7318.50
diff:
-24.50
nom:
7286.00
rdg:
7252.00
diff:
-34.00
nom:
7467.17
rdg:
7426.67
diff:
-40.50
nom:
7303.75
rdg:
7285.00
diff:
-18.75
nom:
7234.00
rdg:
7203.50
diff:
-30.50
nom:
7367.00
rdg:
7416.67
diff:
+49.67
nom:
7112.25
rdg:
7083.50
diff:
-28.75
nom:
7051.00
rdg:
7008.25
diff:
-42.75
nom:
7151.17
rdg:
7110.00
diff:
-41.17
Right riser
nom:
7343.00
rdg:
7318.50
diff:
-24.50
nom:
7286.00
rdg:
7267.50
diff:
-18.50
nom:
7467.17
rdg:
7425.67
diff:
-41.50
nom:
7303.75
rdg:
7284.25
diff:
-19.50
nom:
7234.00
rdg:
7203.50
diff:
-30.50
nom:
7367.00
rdg:
7333.83
diff:
-33.17
nom:
7112.25
rdg:
7084.50
diff:
-27.75
nom:
7051.00
rdg:
7012.00
diff:
-39.00
nom:
7151.17
rdg:
7109.33
diff:
-41.83
Group deviations
Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.
This should be corrected.
Left riser
nom:
6682.75
rdg:
6579.25
diff:
-70.50
nom:
7367.00
rdg:
7416.67
diff:
+82.67
Right riser
nom:
6682.75
rdg:
6583.88
diff:
-65.88
nom:
7367.00
rdg:
7333.83
diff:
-0.17