Review measurement
2025-07-26 10:51
Advance Epsilon 9 28 (2018)
In-group deviations
Readings that are more than 10
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
Right riser
1C1
nom:
7377
rdg:
7364
diff:
+2
1C2
nom:
7320
rdg:
7306
diff:
+1
1D1
nom:
7515
rdg:
7504
diff:
+4
1D2
nom:
7457
rdg:
7441
diff:
-1
Trim
Groups arranged behind each other in flight direction having more than 10
This should be corrected.
Left riser
nom:
7363.50
rdg:
7368.00
diff:
19.50
nom:
7249.50
rdg:
7249.50
diff:
15.00
nom:
7417.25
rdg:
7398.25
diff:
-4.00
nom:
7249.50
rdg:
7254.50
diff:
20.00
nom:
7136.00
rdg:
7134.50
diff:
13.50
nom:
7280.00
rdg:
7272.25
diff:
7.25
Right riser
nom:
7363.50
rdg:
7373.00
diff:
24.50
nom:
7249.50
rdg:
7245.50
diff:
11.00
nom:
7417.25
rdg:
7403.75
diff:
1.50
nom:
7249.50
rdg:
7253.00
diff:
18.50
nom:
7136.00
rdg:
7135.00
diff:
14.00
nom:
7280.00
rdg:
7272.50
diff:
7.50
Group deviations
Groups that are more than 20
The measurement baseline is the median of the deviations of all measurements from their nominal values.
No issues were found