Review measurement

2025-10-11 15:21

Ozone Zeno 2 ML (2022)

Accuracy

Is calculated by comparing each suspension point's length change to the main line's overall change after re-measurement. Deviations over 3.0mm from the average are considered noticeable and may distort the trim result.

Left riser

avg change:
22.22
std dev:
3.15
A9
dev:
+0.2
A10
dev:
-0.8
A11
dev:
-3.8
A12
dev:
-2.8
A13
dev:
-1.8
A14
dev:
-2.8
B12
dev:
+4.2
B13
dev:
+4.2
B14
dev:
+3.2

Right riser

avg change:
10.22
std dev:
1.64
A9
dev:
+2.2
A10
dev:
-1.8
A11
dev:
+0.2
A12
dev:
+0.2
A13
dev:
+0.2
A14
dev:
+0.2
B12
dev:
-2.8
B13
dev:
-0.8
B14
dev:
+2.2

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A9
nom:
7238
rdg:
7205
diff:
-33
A10
nom:
7112
rdg:
7074
diff:
-38
A11
nom:
7043
rdg:
7003
diff:
-40
A12
nom:
6996
rdg:
6951
diff:
-45
A13
nom:
6976
rdg:
6928
diff:
-48
A14
nom:
7018
rdg:
6965
diff:
-53
B12
nom:
7005
rdg:
6961
diff:
-44
B13
nom:
7013
rdg:
6968
diff:
-45
B14
nom:
7041
rdg:
6997
diff:
-44
A1a
nom:
7921
rdg:
7904
diff:
-17
A2a
nom:
7810
rdg:
7788
diff:
-22
A3a
nom:
7771
rdg:
7750
diff:
-21
A4a
nom:
7805
rdg:
7783
diff:
-22
A1b
nom:
7906
rdg:
7884
diff:
-22
A2b
nom:
7795
rdg:
7771
diff:
-24
A3b
nom:
7758
rdg:
7731
diff:
-27
A4b
nom:
7793
rdg:
7766
diff:
-27

Right riser

A9
nom:
7238
rdg:
7214
diff:
-24
A10
nom:
7112
rdg:
7085
diff:
-27
A11
nom:
7043
rdg:
7015
diff:
-28
A12
nom:
6996
rdg:
6962
diff:
-34
A13
nom:
6976
rdg:
6942
diff:
-34
A14
nom:
7018
rdg:
6983
diff:
-35
B12
nom:
7005
rdg:
6968
diff:
-37
B13
nom:
7013
rdg:
6977
diff:
-36
B14
nom:
7041
rdg:
7006
diff:
-35
A1a
nom:
7921
rdg:
7901
diff:
-20
A2a
nom:
7810
rdg:
7793
diff:
-17
A3a
nom:
7771
rdg:
7752
diff:
-19
A4a
nom:
7805
rdg:
7783
diff:
-22
A1b
nom:
7906
rdg:
7885
diff:
-21
A2b
nom:
7795
rdg:
7774
diff:
-21
A3b
nom:
7758
rdg:
7735
diff:
-23
A4b
nom:
7793
rdg:
7765
diff:
-28

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

This should be corrected.

Left riser

nom:
7131.00
rdg:
7094.00
diff:
-37.00
nom:
7155.33
rdg:
7135.33
diff:
-20.00

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

This should be corrected.

Left riser

nom:
7131.00
rdg:
7094.00
diff:
-16.00

Right riser

nom:
7131.00
rdg:
7104.67
diff:
-5.33

Buy us coffee