Review measurement
2025-07-05 11:39
Ozone Enzo 3 M (2017)
In-group deviations
Readings that are more than 10
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
No issues were found
Trim
Groups arranged behind each other in flight direction having more than 10
This should be corrected.
Left riser
nom:
7952.75
rdg:
7953.50
diff:
0.75
nom:
7953.00
rdg:
7966.00
diff:
13.00
Right riser
nom:
8218.13
rdg:
8209.63
diff:
-8.50
nom:
8191.00
rdg:
8196.13
diff:
5.13
nom:
7952.75
rdg:
7949.88
diff:
-2.88
nom:
7953.00
rdg:
7962.63
diff:
9.63
Group deviations
Groups that are more than 20
The measurement baseline is the median of the deviations of all measurements from their nominal values.
No issues were found