Review measurement
2023-04-15 20:40
UP Meru S/M (2018)
In-group deviations
Readings that are more than 10
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
a9
nom:
7103
rdg:
7176
diff:
+73
a10
nom:
7000
rdg:
7072
diff:
+72
a11
nom:
6947
rdg:
7021
diff:
+74
a12
nom:
6963
rdg:
7035
diff:
+72
b9
nom:
7081
rdg:
7152
diff:
+71
Right riser
c1
nom:
7619
rdg:
7691
diff:
+72
c2
nom:
7510
rdg:
7585
diff:
+75
c3
nom:
7476
rdg:
7554
diff:
+78
c4
nom:
7528
rdg:
7605
diff:
+77
d1
nom:
7693
rdg:
7765
diff:
+72
d2
nom:
7590
rdg:
7667
diff:
+77
d3
nom:
7561
rdg:
7635
diff:
+74
d4
nom:
7604
rdg:
7678
diff:
+74
a9
nom:
7103
rdg:
7169
diff:
+66
a10
nom:
7000
rdg:
7074
diff:
+74
a11
nom:
6947
rdg:
7024
diff:
+77
a12
nom:
6963
rdg:
7040
diff:
+77
b9
nom:
7081
rdg:
7148
diff:
+67
Trim
Groups arranged behind each other in flight direction having more than 10
No issues were found
Group deviations
Groups that are more than 20
The measurement baseline is the median (77) of the deviations of all measurements from their nominal values.
No issues were found