Review measurement
2025-03-23 15:33
Ozone Zeno 2 MS (2022)
In-group deviations
Readings that are more than 10
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
Right riser
A9
nom:
6992
rdg:
7001
diff:
+9
A10
nom:
6871
rdg:
6884
diff:
+13
A11
nom:
6806
rdg:
6818
diff:
+12
A12
nom:
6761
rdg:
6769
diff:
+8
A13
nom:
6742
rdg:
6749
diff:
+7
A14
nom:
6782
rdg:
6783
diff:
+1
B12
nom:
6769
rdg:
6776
diff:
+7
B13
nom:
6778
rdg:
6787
diff:
+9
B14
nom:
6805
rdg:
6806
diff:
+1
Trim
Groups arranged behind each other in flight direction having more than 10
This should be corrected.
Left riser
nom:
7552.63
rdg:
7557.63
diff:
5.00
nom:
7561.63
rdg:
7577.38
diff:
15.75
Group deviations
Groups that are more than 20
The measurement baseline is the median of the deviations of all measurements from their nominal values.
No issues were found