Review measurement

2025-08-02 10:37

Ozone Zeolite GT ML (2019)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A15
nom:
6318
rdg:
6840
diff:
 -3
A16
nom:
6264
rdg:
6780
diff:
 -9
A17
nom:
6254
rdg:
6769
diff:
-10
B15
nom:
6342
rdg:
6866
diff:
 -1
B16
nom:
6313
rdg:
6833
diff:
 -5
B17
nom:
6298
rdg:
6811
diff:
-12

Right riser

A15
nom:
6318
rdg:
6840
diff:
 -3
A16
nom:
6264
rdg:
6778
diff:
-11
A17
nom:
6254
rdg:
6767
diff:
-12
B15
nom:
6342
rdg:
6861
diff:
 -6
B16
nom:
6313
rdg:
6828
diff:
-10
B17
nom:
6298
rdg:
6811
diff:
-12

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

This should be corrected.

Left riser

nom:
7638.75
rdg:
7631.88
diff:
-6.88
nom:
7637.00
rdg:
7640.50
diff:
3.50

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found

Buy us coffee