Ozone Zeolite ML (2019)
In-group deviations
Readings that are more than 10
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
Right riser
A15
        nom:
6318
rdg:
6840
diff:
 -3
A16
        nom:
6264
rdg:
6779
diff:
-10
A17
        nom:
6254
rdg:
6770
diff:
 -9
B15
        nom:
6342
rdg:
6862
diff:
 -5
B16
        nom:
6313
rdg:
6827
diff:
-11
B17
        nom:
6298
rdg:
6809
diff:
-14
Trim
                            Groups arranged behind each other in flight direction having more than 10
No issues were found
Group deviations
                                Groups that are more than 20
The measurement baseline is the median of the deviations of all measurements from their nominal values.
                            
No issues were found