Review measurement
2024-04-07 20:50
Ozone Zeno 2 S (2022)
In-group deviations
Readings that are more than 10
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
No issues were found
Trim
Groups arranged behind each other in flight direction having more than 10
This should be corrected.
Left riser
nom:
6655.00
rdg:
6634.00
diff:
-21.00
nom:
6660.33
rdg:
6651.33
diff:
-9.00
Right riser
nom:
6655.00
rdg:
6628.67
diff:
-26.33
nom:
6660.33
rdg:
6647.33
diff:
-13.00
Group deviations
Groups that are more than 20
The measurement baseline is the median of the deviations of all measurements from their nominal values.
No issues were found