Review measurement

2025-09-11 12:18

Ozone Enzo 3 L (2017)

Accuracy

Is calculated by comparing each suspension point's length change to the main line's overall change after re-measurement. Deviations over 3.0mm from the average are considered noticeable and may distort the trim result.

Left riser

Right riser

avg change:
4.88
std dev:
2.03
A1a
dev:
-2.1
A2a
dev:
+0.9
A3a
dev:
-1.1
A4a
dev:
-0.1
A1b
dev:
+2.9
A2b
dev:
-2.1
A3b
dev:
-1.1
A4b
dev:
+2.9

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A5a
nom:
8402
rdg:
8406
diff:
 +4
A6a
nom:
8249
rdg:
8248
diff:
 -1
A7a
nom:
8175
rdg:
8177
diff:
 +2
A8a
nom:
8204
rdg:
8207
diff:
 +3
A5b
nom:
8385
rdg:
8390
diff:
 +5
A6b
nom:
8232
rdg:
8232
diff:
 +0
A7b
nom:
8160
rdg:
8163
diff:
 +3
A8b
nom:
8192
rdg:
8196
diff:
 +4

Right riser

A5a
nom:
8402
rdg:
8408
diff:
 +6
A6a
nom:
8249
rdg:
8248
diff:
 -1
A7a
nom:
8175
rdg:
8175
diff:
 +0
A8a
nom:
8204
rdg:
8202
diff:
 -2
A5b
nom:
8385
rdg:
8394
diff:
 +9
A6b
nom:
8232
rdg:
8232
diff:
 +0
A7b
nom:
8160
rdg:
8163
diff:
 +3
A8b
nom:
8192
rdg:
8195
diff:
 +3

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

No issues were found

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

This should be corrected.

Left riser

nom:
7601.25
rdg:
7574.75
diff:
-27.50

Right riser

nom:
7601.25
rdg:
7574.75
diff:
-27.50

Buy us coffee