Review measurement

2024-10-07 10:00

Ozone Photon ML (2023)

In-group deviations

Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A5a
nom:
7324
rdg:
7322
diff:
-2
A6a
nom:
7184
rdg:
7183
diff:
-1
A7a
nom:
7112
rdg:
7106
diff:
-6
A8a
nom:
7123
rdg:
7117
diff:
-6
A5b
nom:
7313
rdg:
7311
diff:
-2
A6b
nom:
7173
rdg:
7172
diff:
-1
A7b
nom:
7104
rdg:
7093
diff:
-11
A8b
nom:
7118
rdg:
7106
diff:
-12

Right riser

A5a
nom:
7324
rdg:
7319
diff:
-5
A6a
nom:
7184
rdg:
7176
diff:
-8
A7a
nom:
7112
rdg:
7107
diff:
-5
A8a
nom:
7123
rdg:
7110
diff:
-13
A5b
nom:
7313
rdg:
7309
diff:
-4
A6b
nom:
7173
rdg:
7167
diff:
-6
A7b
nom:
7104
rdg:
7096
diff:
-8
A8b
nom:
7118
rdg:
7105
diff:
-13

Trim

Groups arranged behind each other in flight direction having more than 10 mm deviation.

No issues were found

Group deviations

Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found