Review measurement
2024-10-07 10:00
Ozone Photon ML (2023)
In-group deviations
Readings that are more than 10
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
Right riser
A5a
        nom:
7324
rdg:
7319
diff:
 -5
A6a
        nom:
7184
rdg:
7176
diff:
 -8
A7a
        nom:
7112
rdg:
7107
diff:
 -5
A8a
        nom:
7123
rdg:
7110
diff:
-13
A5b
        nom:
7313
rdg:
7309
diff:
 -4
A6b
        nom:
7173
rdg:
7167
diff:
 -6
A7b
        nom:
7104
rdg:
7096
diff:
 -8
A8b
        nom:
7118
rdg:
7105
diff:
-13
Trim
                            Groups arranged behind each other in flight direction having more than 10
No issues were found
Group deviations
                                Groups that are more than 20
The measurement baseline is the median of the deviations of all measurements from their nominal values.
                            
No issues were found