Review measurement

2025-08-10 07:00

PHI Scala 2 Light 19 (2023)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

1C1
nom:
7150
rdg:
7664
diff:
 -1
1C2
nom:
7108
rdg:
7622
diff:
 -1
1C3
nom:
7082
rdg:
7593
diff:
 -4
1C4
nom:
7104
rdg:
7615
diff:
 -4
1D1
nom:
7259
rdg:
7773
diff:
 -1
1D2
nom:
7218
rdg:
7735
diff:
 +2
1D3
nom:
7189
rdg:
7709
diff:
 +5
1D4
nom:
7207
rdg:
7730
diff:
 +8

Right riser

1C1
nom:
7150
rdg:
7661
diff:
 -4
1C2
nom:
7108
rdg:
7623
diff:
 +0
1C3
nom:
7082
rdg:
7597
diff:
 +0
1C4
nom:
7104
rdg:
7620
diff:
 +1
1D1
nom:
7259
rdg:
7774
diff:
 +0
1D2
nom:
7218
rdg:
7736
diff:
 +3
1D3
nom:
7189
rdg:
7708
diff:
 +4
1D4
nom:
7207
rdg:
7726
diff:
 +4

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

This should be corrected.

Left riser

Right riser

nom:
7154.50
rdg:
7119.88
diff:
-9.63
nom:
7140.00
rdg:
7117.00
diff:
2.00

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found

Buy us coffee