Review measurement
2025-08-10 07:00
PHI Scala 2 Light 19 (2023)
In-group deviations
Readings that are more than 10
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
Right riser
1C1
nom:
7150
rdg:
7661
diff:
-4
1C2
nom:
7108
rdg:
7623
diff:
+0
1C3
nom:
7082
rdg:
7597
diff:
+0
1C4
nom:
7104
rdg:
7620
diff:
+1
1D1
nom:
7259
rdg:
7774
diff:
+0
1D2
nom:
7218
rdg:
7736
diff:
+3
1D3
nom:
7189
rdg:
7708
diff:
+4
1D4
nom:
7207
rdg:
7726
diff:
+4
Trim
Groups arranged behind each other in flight direction having more than 10
This should be corrected.
Left riser
Right riser
nom:
7154.50
rdg:
7119.88
diff:
-9.63
nom:
7140.00
rdg:
7117.00
diff:
2.00
Group deviations
Groups that are more than 20
The measurement baseline is the median of the deviations of all measurements from their nominal values.
No issues were found