Review measurement
2026-08-10 11:32
Ozone Lyght ML (2024)
In-group deviations
Readings that are more than 10
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
A5a
nom:
7331
rdg:
7320
diff:
-11
A6a
nom:
7190
rdg:
7180
diff:
-10
A7a
nom:
7117
rdg:
7108
diff:
-9
A8a
nom:
7128
rdg:
7115
diff:
-13
A5b
nom:
7321
rdg:
7309
diff:
-12
A6b
nom:
7180
rdg:
7168
diff:
-12
A7b
nom:
7110
rdg:
7100
diff:
-10
A8b
nom:
7124
rdg:
7114
diff:
-10
Right riser
A9
nom:
6946
rdg:
6929
diff:
-17
A10
nom:
6818
rdg:
6802
diff:
-16
A11
nom:
6746
rdg:
6736
diff:
-10
A12
nom:
6670
rdg:
6662
diff:
-8
A13
nom:
6663
rdg:
6653
diff:
-10
B12
nom:
6691
rdg:
6684
diff:
-7
B13
nom:
6690
rdg:
6656
diff:
-34
A5a
nom:
7331
rdg:
7321
diff:
-10
A6a
nom:
7190
rdg:
7181
diff:
-9
A7a
nom:
7117
rdg:
7114
diff:
-3
A8a
nom:
7128
rdg:
7119
diff:
-9
A5b
nom:
7321
rdg:
7305
diff:
-16
A6b
nom:
7180
rdg:
7170
diff:
-10
A7b
nom:
7110
rdg:
7107
diff:
-3
A8b
nom:
7124
rdg:
7117
diff:
-7
Trim
Groups arranged behind each other in flight direction having more than 10
No issues were found
Group deviations
Groups that are more than 20
The measurement baseline is the median (-12) of the deviations of all measurements from their nominal values.
No issues were found