Review measurement

2024-05-25 09:09

Ozone Zeno 2 MS (2022)

In-group deviations

Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A1a
nom:
7651
rdg:
7646
diff:
-5
A2a
nom:
7543
rdg:
7542
diff:
-1
A3a
nom:
7506
rdg:
7506
diff:
+0
A4a
nom:
7539
rdg:
7531
diff:
-8
A1b
nom:
7636
rdg:
7628
diff:
-8
A2b
nom:
7528
rdg:
7525
diff:
-3
A3b
nom:
7492
rdg:
7481
diff:
-11
A4b
nom:
7526
rdg:
7517
diff:
-9
A9
nom:
6992
rdg:
6983
diff:
-9
A10
nom:
6871
rdg:
6869
diff:
-2
A11
nom:
6806
rdg:
6804
diff:
-2
A12
nom:
6761
rdg:
6765
diff:
+4
A13
nom:
6742
rdg:
6751
diff:
+9
A14
nom:
6782
rdg:
6790
diff:
+8
B12
nom:
6769
rdg:
6779
diff:
+10
B13
nom:
6778
rdg:
6789
diff:
+11
B14
nom:
6805
rdg:
6811
diff:
+6
B1
nom:
7614
rdg:
7615
diff:
+1
B2
nom:
7517
rdg:
7519
diff:
+2
B3
nom:
7481
rdg:
7480
diff:
-1
B4
nom:
7502
rdg:
7503
diff:
+1
C1
nom:
7680
rdg:
7689
diff:
+9
C2
nom:
7586
rdg:
7592
diff:
+6
C3
nom:
7548
rdg:
7556
diff:
+8
C4
nom:
7565
rdg:
7566
diff:
+1

Right riser

A1a
nom:
7651
rdg:
7645
diff:
-6
A2a
nom:
7543
rdg:
7534
diff:
-9
A3a
nom:
7506
rdg:
7501
diff:
-5
A4a
nom:
7539
rdg:
7529
diff:
-10
A1b
nom:
7636
rdg:
7625
diff:
-11
A2b
nom:
7528
rdg:
7521
diff:
-7
A3b
nom:
7492
rdg:
7488
diff:
-4
A4b
nom:
7526
rdg:
7515
diff:
-11
A9
nom:
6992
rdg:
6982
diff:
-10
A10
nom:
6871
rdg:
6868
diff:
-3
A11
nom:
6806
rdg:
6803
diff:
-3
A12
nom:
6761
rdg:
6762
diff:
+1
A13
nom:
6742
rdg:
6740
diff:
-2
A14
nom:
6782
rdg:
6782
diff:
+0
B12
nom:
6769
rdg:
6767
diff:
-2
B13
nom:
6778
rdg:
6780
diff:
+2
B14
nom:
6805
rdg:
6806
diff:
+1
B1
nom:
7614
rdg:
7613
diff:
-1
B2
nom:
7517
rdg:
7516
diff:
-1
B3
nom:
7481
rdg:
7479
diff:
-2
B4
nom:
7502
rdg:
7493
diff:
-9
C1
nom:
7680
rdg:
7682
diff:
+2
C2
nom:
7586
rdg:
7591
diff:
+5
C3
nom:
7548
rdg:
7547
diff:
-1
C4
nom:
7565
rdg:
7569
diff:
+4

Trim

Groups arranged behind each other in flight direction having more than 10 mm deviation.

No issues were found

Group deviations

Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found