Review measurement

2023-05-12 17:56

Ozone Zeno 2 ML (2022)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A9
nom:
7238
rdg:
7238
diff:
 +0
A10
nom:
7112
rdg:
7109
diff:
 -3
A11
nom:
7043
rdg:
7044
diff:
 +1
A12
nom:
6996
rdg:
6989
diff:
 -7
A13
nom:
6976
rdg:
6973
diff:
 -3
A14
nom:
7018
rdg:
7005
diff:
-13
B12
nom:
7005
rdg:
6994
diff:
-11
B13
nom:
7013
rdg:
7002
diff:
-11
B14
nom:
7041
rdg:
7025
diff:
-16
A1a
nom:
7921
rdg:
7922
diff:
 +1
A2a
nom:
7810
rdg:
7808
diff:
 -2
A3a
nom:
7771
rdg:
7768
diff:
 -3
A4a
nom:
7805
rdg:
7801
diff:
 -4
A1b
nom:
7906
rdg:
7903
diff:
 -3
A2b
nom:
7795
rdg:
7793
diff:
 -2
A3b
nom:
7758
rdg:
7752
diff:
 -6
A4b
nom:
7793
rdg:
7791
diff:
 -2
B5
nom:
7661
rdg:
7662
diff:
 +1
B6
nom:
7519
rdg:
7522
diff:
 +3
B7
nom:
7441
rdg:
7443
diff:
 +2
B8
nom:
7451
rdg:
7452
diff:
 +1
C5
nom:
7738
rdg:
7745
diff:
 +7
C6
nom:
7595
rdg:
7603
diff:
 +8
C7
nom:
7512
rdg:
7517
diff:
 +5
C8
nom:
7512
rdg:
7514
diff:
 +2

Right riser

A9
nom:
7238
rdg:
7238
diff:
 +0
A10
nom:
7112
rdg:
7109
diff:
 -3
A11
nom:
7043
rdg:
7041
diff:
 -2
A12
nom:
6996
rdg:
6991
diff:
 -5
A13
nom:
6976
rdg:
6973
diff:
 -3
A14
nom:
7018
rdg:
7009
diff:
 -9
B12
nom:
7005
rdg:
6997
diff:
 -8
B13
nom:
7013
rdg:
7004
diff:
 -9
B14
nom:
7041
rdg:
7031
diff:
-10
A1a
nom:
7921
rdg:
7929
diff:
 +8
A2a
nom:
7810
rdg:
7811
diff:
 +1
A3a
nom:
7771
rdg:
7773
diff:
 +2
A4a
nom:
7805
rdg:
7805
diff:
 +0
A1b
nom:
7906
rdg:
7906
diff:
 +0
A2b
nom:
7795
rdg:
7792
diff:
 -3
A3b
nom:
7758
rdg:
7761
diff:
 +3
A4b
nom:
7793
rdg:
7792
diff:
 -1
B5
nom:
7661
rdg:
7668
diff:
 +7
B6
nom:
7519
rdg:
7524
diff:
 +5
B7
nom:
7441
rdg:
7444
diff:
 +3
B8
nom:
7451
rdg:
7452
diff:
 +1
C5
nom:
7738
rdg:
7750
diff:
+12
C6
nom:
7595
rdg:
7605
diff:
+10
C7
nom:
7512
rdg:
7518
diff:
 +6
C8
nom:
7512
rdg:
7517
diff:
 +5

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

No issues were found

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found

Buy us coffee