Review measurement

2025-12-31 20:48

Ozone Zeno 2 ML (2022)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A9
nom:
7238
rdg:
7240
diff:
 +2
A10
nom:
7112
rdg:
7120
diff:
 +8
A11
nom:
7043
rdg:
7051
diff:
 +8
A12
nom:
6996
rdg:
6991
diff:
 -5
A13
nom:
6976
rdg:
6974
diff:
 -2
A14
nom:
7018
rdg:
7011
diff:
 -7
B12
nom:
7005
rdg:
6998
diff:
 -7
B13
nom:
7013
rdg:
6999
diff:
-14
B14
nom:
7041
rdg:
7032
diff:
 -9
A5a
nom:
7697
rdg:
7709
diff:
+12
A6a
nom:
7538
rdg:
7547
diff:
 +9
A7a
nom:
7461
rdg:
7470
diff:
 +9
A8a
nom:
7488
rdg:
7495
diff:
 +7
A5b
nom:
7687
rdg:
7693
diff:
 +6
A6b
nom:
7529
rdg:
7536
diff:
 +7
A7b
nom:
7456
rdg:
7467
diff:
+11
A8b
nom:
7486
rdg:
7488
diff:
 +2
B5
nom:
7661
rdg:
7660
diff:
 -1
B6
nom:
7519
rdg:
7522
diff:
 +3
B7
nom:
7441
rdg:
7441
diff:
 +0
B8
nom:
7451
rdg:
7452
diff:
 +1
C5
nom:
7738
rdg:
7737
diff:
 -1
C6
nom:
7595
rdg:
7597
diff:
 +2
C7
nom:
7512
rdg:
7516
diff:
 +4
C8
nom:
7512
rdg:
7513
diff:
 +1

Right riser

A9
nom:
7238
rdg:
7239
diff:
 +1
A10
nom:
7112
rdg:
7116
diff:
 +4
A11
nom:
7043
rdg:
7046
diff:
 +3
A12
nom:
6996
rdg:
6988
diff:
 -8
A13
nom:
6976
rdg:
6970
diff:
 -6
A14
nom:
7018
rdg:
7010
diff:
 -8
B12
nom:
7005
rdg:
6998
diff:
 -7
B13
nom:
7013
rdg:
7004
diff:
 -9
B14
nom:
7041
rdg:
7031
diff:
-10
A5a
nom:
7697
rdg:
7706
diff:
 +9
A6a
nom:
7538
rdg:
7547
diff:
 +9
A7a
nom:
7461
rdg:
7469
diff:
 +8
A8a
nom:
7488
rdg:
7495
diff:
 +7
A5b
nom:
7687
rdg:
7697
diff:
+10
A6b
nom:
7529
rdg:
7541
diff:
+12
A7b
nom:
7456
rdg:
7457
diff:
 +1
A8b
nom:
7486
rdg:
7487
diff:
 +1
B5
nom:
7661
rdg:
7654
diff:
 -7
B6
nom:
7519
rdg:
7524
diff:
 +5
B7
nom:
7441
rdg:
7439
diff:
 -2
B8
nom:
7451
rdg:
7446
diff:
 -5
C5
nom:
7738
rdg:
7738
diff:
 +0
C6
nom:
7595
rdg:
7598
diff:
 +3
C7
nom:
7512
rdg:
7511
diff:
 -1
C8
nom:
7512
rdg:
7509
diff:
 -3

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

No issues were found

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found