Review measurement

2026-03-08 13:21

Niviuk Klimber 3 P 23 (2023)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

c9
nom:
7251
rdg:
7195
diff:
-56
c10
nom:
7220
rdg:
7166
diff:
-54
c11
nom:
7113
rdg:
7064
diff:
-49
c12
nom:
7085
rdg:
7037
diff:
-48
c13
nom:
7032
rdg:
6983
diff:
-49
c14
nom:
7027
rdg:
6977
diff:
-50
d9
nom:
7334
rdg:
7281
diff:
-53
d10
nom:
7291
rdg:
7231
diff:
-60

Right riser

c9
nom:
7251
rdg:
7202
diff:
-49
c10
nom:
7220
rdg:
7171
diff:
-49
c11
nom:
7113
rdg:
7063
diff:
-50
c12
nom:
7085
rdg:
7036
diff:
-49
c13
nom:
7032
rdg:
6989
diff:
-43
c14
nom:
7027
rdg:
6974
diff:
-53
d9
nom:
7334
rdg:
7282
diff:
-52
d10
nom:
7291
rdg:
7235
diff:
-56

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

This should be corrected.

Left riser

nom:
7140.33
rdg:
7110.33
diff:
-30.00
nom:
7169.13
rdg:
7116.75
diff:
-52.38

Right riser

nom:
7140.33
rdg:
7106.00
diff:
-34.33
nom:
7169.13
rdg:
7119.00
diff:
-50.13

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found