Review measurement

2026-03-08 13:21

Niviuk Klimber 3 P 23 (2023)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

c9
nom:
7251
rdg:
7195
diff:
-56
c10
nom:
7220
rdg:
7166
diff:
-54
c11
nom:
7113
rdg:
7064
diff:
-49
c12
nom:
7085
rdg:
7037
diff:
-48
c13
nom:
7032
rdg:
6983
diff:
-49
c14
nom:
7027
rdg:
6977
diff:
-50
d9
nom:
7334
rdg:
7281
diff:
-53
d10
nom:
7291
rdg:
7231
diff:
-60

Right riser

c9
nom:
7251
rdg:
7202
diff:
-49
c10
nom:
7220
rdg:
7171
diff:
-49
c11
nom:
7113
rdg:
7063
diff:
-50
c12
nom:
7085
rdg:
7036
diff:
-49
c13
nom:
7032
rdg:
6989
diff:
-43
c14
nom:
7027
rdg:
6974
diff:
-53
d9
nom:
7334
rdg:
7282
diff:
-52
d10
nom:
7291
rdg:
7235
diff:
-56

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

This should be corrected.

Left riser

nom:
7140.33
rdg:
7110.33
diff:
-30.00
nom:
7169.13
rdg:
7116.75
diff:
-52.38

Right riser

nom:
7140.33
rdg:
7106.00
diff:
-34.33
nom:
7169.13
rdg:
7119.00
diff:
-50.13

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median (-43) of the deviations of all measurements from their nominal values.

No issues were found