Review measurement

2024-04-18 16:46

Ozone Zeno 2 ML (2022)

Accuracy

Is calculated by comparing each suspension point's length change to the main line's overall change after re-measurement. Deviations over 3.0mm from the average are considered noticeable and may distort the trim result.

Left riser

Right riser

avg change:
1.22
std dev:
2.64
A9
dev:
-2.2
A10
dev:
+0.8
A11
dev:
-1.2
A12
dev:
-1.2
A13
dev:
+3.8
A14
dev:
+3.8
B12
dev:
-4.2
B13
dev:
+0.8
B14
dev:
-0.2
avg change:
9.33
std dev:
1.15
B9
dev:
-0.7
B10
dev:
-0.7
B11
dev:
+1.3

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A9
nom:
7238
rdg:
7228
diff:
-10
A10
nom:
7112
rdg:
7107
diff:
 -5
A11
nom:
7043
rdg:
7040
diff:
 -3
A12
nom:
6996
rdg:
6983
diff:
-13
A13
nom:
6976
rdg:
6969
diff:
 -7
A14
nom:
7018
rdg:
7010
diff:
 -8
B12
nom:
7005
rdg:
6994
diff:
-11
B13
nom:
7013
rdg:
7006
diff:
 -7
B14
nom:
7041
rdg:
7031
diff:
-10

Right riser

A9
nom:
7238
rdg:
7220
diff:
-18
A10
nom:
7112
rdg:
7104
diff:
 -8
A11
nom:
7043
rdg:
7035
diff:
 -8
A12
nom:
6996
rdg:
6984
diff:
-12
A13
nom:
6976
rdg:
6967
diff:
 -9
A14
nom:
7018
rdg:
7007
diff:
-11
B12
nom:
7005
rdg:
6986
diff:
-19
B13
nom:
7013
rdg:
7000
diff:
-13
B14
nom:
7041
rdg:
7031
diff:
-10

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

This should be corrected.

Left riser

nom:
7131.00
rdg:
7125.00
diff:
-6.00
nom:
7155.33
rdg:
7134.67
diff:
-20.67

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median (-7) of the deviations of all measurements from their nominal values.

No issues were found