Review measurement
2023-07-16 09:07
Ozone Zeno 2 MS (2022)
In-group deviations
Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
A5a
nom:
7435
rdg:
7442
diff:
+7
A6a
nom:
7281
rdg:
7286
diff:
+5
A7a
nom:
7206
rdg:
7208
diff:
+2
A8a
nom:
7233
rdg:
7240
diff:
+7
A5b
nom:
7425
rdg:
7432
diff:
+7
A6b
nom:
7273
rdg:
7273
diff:
+0
A7b
nom:
7201
rdg:
7203
diff:
+2
A8b
nom:
7230
rdg:
7231
diff:
+1
Right riser
A1a
nom:
7651
rdg:
7653
diff:
+2
A2a
nom:
7543
rdg:
7548
diff:
+5
A3a
nom:
7506
rdg:
7513
diff:
+7
A4a
nom:
7539
rdg:
7541
diff:
+2
A1b
nom:
7636
rdg:
7636
diff:
+0
A2b
nom:
7528
rdg:
7533
diff:
+5
A3b
nom:
7492
rdg:
7497
diff:
+5
A4b
nom:
7526
rdg:
7526
diff:
+0
A5a
nom:
7435
rdg:
7439
diff:
+4
A6a
nom:
7281
rdg:
7290
diff:
+9
A7a
nom:
7206
rdg:
7214
diff:
+8
A8a
nom:
7233
rdg:
7237
diff:
+4
A5b
nom:
7425
rdg:
7427
diff:
+2
A6b
nom:
7273
rdg:
7281
diff:
+8
A7b
nom:
7201
rdg:
7203
diff:
+2
A8b
nom:
7230
rdg:
7228
diff:
-2
Trim
Groups arranged behind each other in flight direction having more than 10 mm deviation.
No issues were found
Group deviations
Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.
No issues were found