Review measurement
2026-03-30 17:04
Ozone Enzo 3 M (2017)
In-group deviations
Readings that are more than 10
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
A15
nom:
7336
rdg:
7316
diff:
-20
A16
nom:
7311
rdg:
7293
diff:
-18
B24
nom:
7343
rdg:
7328
diff:
-15
B25
nom:
7342
rdg:
7324
diff:
-18
Right riser
A5a
nom:
8099
rdg:
8078
diff:
-21
A6a
nom:
7952
rdg:
7931
diff:
-21
A7a
nom:
7881
rdg:
7866
diff:
-15
A8a
nom:
7909
rdg:
7892
diff:
-17
A5b
nom:
8082
rdg:
8060
diff:
-22
A6b
nom:
7936
rdg:
7914
diff:
-22
A7b
nom:
7866
rdg:
7854
diff:
-12
A8b
nom:
7897
rdg:
7888
diff:
-9
A15
nom:
7336
rdg:
7313
diff:
-23
A16
nom:
7311
rdg:
7286
diff:
-25
B24
nom:
7343
rdg:
7333
diff:
-10
B25
nom:
7342
rdg:
7329
diff:
-13
Trim
Groups arranged behind each other in flight direction having more than 10
No issues were found
Group deviations
Groups that are more than 20
The measurement baseline is the median of the deviations of all measurements from their nominal values.
No issues were found