Review measurement
2026-09-01 19:27
Ozone Lyght MS (2024)
In-group deviations
Readings that are more than 10
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
A1a
nom:
7259
rdg:
7261
diff:
+2
A2a
nom:
7157
rdg:
7160
diff:
+3
A3a
nom:
7121
rdg:
7120
diff:
-1
A4a
nom:
7154
rdg:
7153
diff:
-1
A1b
nom:
7245
rdg:
7241
diff:
-4
A2b
nom:
7142
rdg:
7145
diff:
+3
A3b
nom:
7108
rdg:
7107
diff:
-1
A4b
nom:
7142
rdg:
7138
diff:
-4
Right riser
A9
nom:
6702
rdg:
6702
diff:
+0
A10
nom:
6579
rdg:
6582
diff:
+3
A11
nom:
6510
rdg:
6512
diff:
+2
A12
nom:
6437
rdg:
6441
diff:
+4
A13
nom:
6431
rdg:
6436
diff:
+5
B12
nom:
6457
rdg:
6462
diff:
+5
B13
nom:
6457
rdg:
6458
diff:
+1
A1a
nom:
7259
rdg:
7262
diff:
+3
A2a
nom:
7157
rdg:
7156
diff:
-1
A3a
nom:
7121
rdg:
7121
diff:
+0
A4a
nom:
7154
rdg:
7149
diff:
-5
A1b
nom:
7245
rdg:
7242
diff:
-3
A2b
nom:
7142
rdg:
7143
diff:
+1
A3b
nom:
7108
rdg:
7103
diff:
-5
A4b
nom:
7142
rdg:
7134
diff:
-8
Trim
Groups arranged behind each other in flight direction having more than 10
No issues were found
Group deviations
Groups that are more than 20
The measurement baseline is the median (3) of the deviations of all measurements from their nominal values.
No issues were found