Review measurement

2025-09-16 20:50

Ozone Zeno 2 ML (2022)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A9
nom:
7238
rdg:
7225
diff:
-13
A10
nom:
7112
rdg:
7101
diff:
-11
A11
nom:
7043
rdg:
7031
diff:
-12
A12
nom:
6996
rdg:
6978
diff:
-18
A13
nom:
6976
rdg:
6954
diff:
-22
A14
nom:
7018
rdg:
6990
diff:
-28
B12
nom:
7005
rdg:
6987
diff:
-18
B13
nom:
7013
rdg:
6993
diff:
-20
B14
nom:
7041
rdg:
7013
diff:
-28

Right riser

A9
nom:
7238
rdg:
7221
diff:
-17
A10
nom:
7112
rdg:
7095
diff:
-17
A11
nom:
7043
rdg:
7027
diff:
-16
A12
nom:
6996
rdg:
6972
diff:
-24
A13
nom:
6976
rdg:
6951
diff:
-25
A14
nom:
7018
rdg:
6986
diff:
-32
B12
nom:
7005
rdg:
6981
diff:
-24
B13
nom:
7013
rdg:
6986
diff:
-27
B14
nom:
7041
rdg:
7010
diff:
-31

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

No issues were found

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found