Review measurement
2025-01-13 18:06
AirDesign Susi 2 18 (2012)
In-group deviations
Readings that are more than 10
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
C9
nom:
5280
rdg:
5704
diff:
-56
C10
nom:
5125
rdg:
5553
diff:
-52
C11
nom:
4975
rdg:
5395
diff:
-60
Right riser
B9
nom:
5215
rdg:
5631
diff:
-64
B10
nom:
5085
rdg:
5501
diff:
-64
B11
nom:
4980
rdg:
5390
diff:
-70
C9
nom:
5280
rdg:
5703
diff:
-57
C10
nom:
5125
rdg:
5554
diff:
-51
C11
nom:
4975
rdg:
5390
diff:
-65
Trim
Groups arranged behind each other in flight direction having more than 10
This should be corrected.
Left riser
nom:
5590.00
rdg:
5522.67
diff:
-67.33
nom:
5573.33
rdg:
5508.00
diff:
-65.33
nom:
5606.67
rdg:
5550.67
diff:
-56.00
Group deviations
Groups that are more than 20
The measurement baseline is the median of the deviations of all measurements from their nominal values.
No issues were found