Review measurement
2025-01-13 18:06
AirDesign Susi 2 18 (2012)
In-group deviations
Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
C9
nom:
5280
rdg:
5704
diff:
-56
C10
nom:
5125
rdg:
5553
diff:
-52
C11
nom:
4975
rdg:
5395
diff:
-60
Right riser
B9
nom:
5215
rdg:
5631
diff:
-64
B10
nom:
5085
rdg:
5501
diff:
-64
B11
nom:
4980
rdg:
5390
diff:
-70
C9
nom:
5280
rdg:
5703
diff:
-57
C10
nom:
5125
rdg:
5554
diff:
-51
C11
nom:
4975
rdg:
5390
diff:
-65
Trim
Groups arranged behind each other in flight direction having more than 10 mm deviation.
This should be corrected.
Left riser
nom:
5590.00
rdg:
5522.67
diff:
-67.33
nom:
5573.33
rdg:
5508.00
diff:
-65.33
nom:
5606.67
rdg:
5550.67
diff:
-56.00
Group deviations
Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.
No issues were found