Review measurement

2026-04-08 10:16

Ozone Zeolite 2 GT L (2023)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A9
nom:
7311
rdg:
7283
diff:
-28
A10
nom:
7173
rdg:
7148
diff:
-25
A11
nom:
7097
rdg:
7068
diff:
-29
A12
nom:
6996
rdg:
6963
diff:
-33
A13
nom:
6975
rdg:
6942
diff:
-33
B12
nom:
7018
rdg:
6984
diff:
-34
B13
nom:
7001
rdg:
6968
diff:
-33

Right riser

A9
nom:
7311
rdg:
7281
diff:
-30
A10
nom:
7173
rdg:
7146
diff:
-27
A11
nom:
7097
rdg:
7067
diff:
-30
A12
nom:
6996
rdg:
6959
diff:
-37
A13
nom:
6975
rdg:
6937
diff:
-38
B12
nom:
7018
rdg:
6979
diff:
-39
B13
nom:
7001
rdg:
6961
diff:
-40

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

No issues were found

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.