Review measurement

2026-04-10 23:50

Ozone Buzz Z5 XS (2015)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

C9
nom:
5741
rdg:
6165
diff:
-76
C10
nom:
5699
rdg:
6124
diff:
-75
C11
nom:
5617
rdg:
6047
diff:
-70
C12
nom:
5583
rdg:
6011
diff:
-72
D9
nom:
5803
rdg:
6222
diff:
-81
D10
nom:
5756
rdg:
6176
diff:
-80
D11
nom:
5665
rdg:
6092
diff:
-73
D12
nom:
5627
rdg:
6053
diff:
-74

Right riser

C9
nom:
5741
rdg:
6165
diff:
-76
C10
nom:
5699
rdg:
6125
diff:
-74
C11
nom:
5617
rdg:
6044
diff:
-73
C12
nom:
5583
rdg:
6011
diff:
-72
D9
nom:
5803
rdg:
6225
diff:
-78
D10
nom:
5756
rdg:
6179
diff:
-77
D11
nom:
5665
rdg:
6093
diff:
-72
D12
nom:
5627
rdg:
6054
diff:
-73

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

This should be corrected.

Left riser

Right riser

nom:
6193.00
rdg:
6107.00
diff:
-86.00
nom:
6146.00
rdg:
6075.25
diff:
-70.75
nom:
6186.38
rdg:
6112.00
diff:
-74.38

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median (-74) of the deviations of all measurements from their nominal values.

No issues were found