Accuracy

Is calculated by comparing each suspension point's length change to the main line's overall change after re-measurement. Deviations over 3.0mm from the average are considered noticeable and may distort the trim result.

Left riser

avg change:
14.33
std dev:
2.60
A9
dev:
+1.3
A10
dev:
+3.3
A11
dev:
-0.7
A12
dev:
+3.3
A13
dev:
+1.3
A14
dev:
-2.7
B12
dev:
+0.3
B13
dev:
-3.7
B14
dev:
-2.7
avg change:
12.38
std dev:
0.92
B1
dev:
-0.6
B2
dev:
-0.6
B3
dev:
+0.4
B4
dev:
+1.4
C1
dev:
+0.4
C2
dev:
+0.4
C3
dev:
-1.6
C4
dev:
+0.4
avg change:
14.13
std dev:
5.25
B5
dev:
-7.9
B6
dev:
+3.1
B7
dev:
+2.1
B8
dev:
+1.1
C5
dev:
-8.9
C6
dev:
+3.1
C7
dev:
+4.1
C8
dev:
+3.1
avg change:
11.33
std dev:
1.53
B9
dev:
-1.7
B10
dev:
+1.3
B11
dev:
+0.3

Right riser

avg change:
11.44
std dev:
2.35
A9
dev:
-0.6
A10
dev:
+2.4
A11
dev:
+3.4
A12
dev:
-4.6
A13
dev:
-0.6
A14
dev:
-1.6
B12
dev:
-0.6
B13
dev:
+0.4
B14
dev:
+1.4
avg change:
15.38
std dev:
2.67
B1
dev:
-1.6
B2
dev:
-0.6
B3
dev:
+3.4
B4
dev:
-4.6
C1
dev:
+2.4
C2
dev:
+0.4
C3
dev:
-1.6
C4
dev:
+2.4
avg change:
12.50
std dev:
1.93
B5
dev:
-0.5
B6
dev:
-2.5
B7
dev:
+2.5
B8
dev:
+0.5
C5
dev:
+0.5
C6
dev:
-0.5
C7
dev:
-2.5
C8
dev:
+2.5
avg change:
9.33
std dev:
2.08
B9
dev:
-0.7
B10
dev:
-1.7
B11
dev:
+2.3

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

B5
nom:
6665
rdg:
7154
diff:
-21
B6
nom:
6539
rdg:
7021
diff:
-28
B7
nom:
6474
rdg:
6954
diff:
-30
B8
nom:
6488
rdg:
6967
diff:
-31
C5
nom:
6738
rdg:
7212
diff:
-36
C6
nom:
6609
rdg:
7085
diff:
-34
C7
nom:
6537
rdg:
7013
diff:
-34
C8
nom:
6536
rdg:
7011
diff:
-35

Right riser

B5
nom:
6665
rdg:
7139
diff:
-36
B6
nom:
6539
rdg:
7015
diff:
-34
B7
nom:
6474
rdg:
6952
diff:
-32
B8
nom:
6488
rdg:
6966
diff:
-32
C5
nom:
6738
rdg:
7208
diff:
-40
C6
nom:
6609
rdg:
7077
diff:
-42
C7
nom:
6537
rdg:
7002
diff:
-45
C8
nom:
6536
rdg:
7010
diff:
-36

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

This should be corrected.

Left riser

nom:
6724.33
rdg:
6683.67
diff:
-40.67
nom:
6724.67
rdg:
6695.00
diff:
-29.67

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median (-36) of the deviations of all measurements from their nominal values.