Review measurement
2025-06-12 09:47
Ozone Zeolite 2 GT L (2023)
In-group deviations
Readings that are more than 10
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
B1
nom:
7877
rdg:
7854
diff:
-23
B2
nom:
7766
rdg:
7745
diff:
-21
B3
nom:
7729
rdg:
7705
diff:
-24
B4
nom:
7764
rdg:
7738
diff:
-26
C1
nom:
7957
rdg:
7938
diff:
-19
C2
nom:
7850
rdg:
7826
diff:
-24
C3
nom:
7810
rdg:
7788
diff:
-22
C4
nom:
7839
rdg:
7814
diff:
-25
Right riser
A9
nom:
7311
rdg:
7278
diff:
-33
A10
nom:
7173
rdg:
7144
diff:
-29
A11
nom:
7097
rdg:
7061
diff:
-36
A12
nom:
6996
rdg:
6956
diff:
-40
A13
nom:
6975
rdg:
6936
diff:
-39
B12
nom:
7018
rdg:
6980
diff:
-38
B13
nom:
7001
rdg:
6963
diff:
-38
B1
nom:
7877
rdg:
7854
diff:
-23
B2
nom:
7766
rdg:
7746
diff:
-20
B3
nom:
7729
rdg:
7703
diff:
-26
B4
nom:
7764
rdg:
7739
diff:
-25
C1
nom:
7957
rdg:
7933
diff:
-24
C2
nom:
7850
rdg:
7830
diff:
-20
C3
nom:
7810
rdg:
7783
diff:
-27
C4
nom:
7839
rdg:
7808
diff:
-31
Trim
Groups arranged behind each other in flight direction having more than 10
No issues were found
Group deviations
Groups that are more than 20
The measurement baseline is the median of the deviations of all measurements from their nominal values.
No issues were found