Review measurement
2024-05-17 09:14
Ozone Enzo 3 M (2017)
In-group deviations
Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
Right riser
B9
nom:
8108
rdg:
8117
diff:
+9
B10
nom:
8055
rdg:
8068
diff:
+13
B11
nom:
7946
rdg:
7958
diff:
+12
B12
nom:
7940
rdg:
7955
diff:
+15
B13
nom:
7888
rdg:
7908
diff:
+20
B14
nom:
7872
rdg:
7893
diff:
+21
B15
nom:
7895
rdg:
7912
diff:
+17
B16
nom:
7920
rdg:
7940
diff:
+20
Trim
Groups arranged behind each other in flight direction having more than 10 mm deviation.
This should be corrected.
Left riser
nom:
8218.13
rdg:
8224.00
diff:
+5.88
nom:
8191.00
rdg:
8207.00
diff:
+16.00
Group deviations
Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.
No issues were found