Review measurement

2024-05-17 09:14

Ozone Enzo 3 M (2017)

In-group deviations

Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

B9
nom:
8108
rdg:
8120
diff:
+12
B10
nom:
8055
rdg:
8068
diff:
+13
B11
nom:
7946
rdg:
7962
diff:
+16
B12
nom:
7940
rdg:
7956
diff:
+16
B13
nom:
7888
rdg:
7907
diff:
+19
B14
nom:
7872
rdg:
7890
diff:
+18
B15
nom:
7895
rdg:
7913
diff:
+18
B16
nom:
7920
rdg:
7940
diff:
+20

Right riser

B9
nom:
8108
rdg:
8117
diff:
+9
B10
nom:
8055
rdg:
8068
diff:
+13
B11
nom:
7946
rdg:
7958
diff:
+12
B12
nom:
7940
rdg:
7955
diff:
+15
B13
nom:
7888
rdg:
7908
diff:
+20
B14
nom:
7872
rdg:
7893
diff:
+21
B15
nom:
7895
rdg:
7912
diff:
+17
B16
nom:
7920
rdg:
7940
diff:
+20

Trim

Groups arranged behind each other in flight direction having more than 10 mm deviation.

This should be corrected.

Left riser

nom:
8218.13
rdg:
8224.00
diff:
+5.88
nom:
8191.00
rdg:
8207.00
diff:
+16.00

Group deviations

Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found

Buy us a