Review measurement

2024-04-18 16:56

Ozone Zeno 2 ML (2022)

Accuracy

Is calculated by comparing each suspension point's length change to the main line's overall change after re-measurement. Deviations over 3.0mm from the average are considered noticeable and may distort the trim result.

Left riser

avg change:
1.56
std dev:
2.74
A9
dev:
+0.6
A10
dev:
-1.4
A11
dev:
-0.4
A12
dev:
+5.6
A13
dev:
+0.6
A14
dev:
-1.4
B12
dev:
-3.4
B13
dev:
-2.4
B14
dev:
+2.6
avg change:
10.33
std dev:
2.52
B9
dev:
+0.3
B10
dev:
-2.7
B11
dev:
+2.3

Right riser

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A9
nom:
7238
rdg:
7227
diff:
-11
A10
nom:
7112
rdg:
7104
diff:
 -8
A11
nom:
7043
rdg:
7038
diff:
 -5
A12
nom:
6996
rdg:
6987
diff:
 -9
A13
nom:
6976
rdg:
6968
diff:
 -8
A14
nom:
7018
rdg:
7007
diff:
-11
B12
nom:
7005
rdg:
6989
diff:
-16
B13
nom:
7013
rdg:
7002
diff:
-11
B14
nom:
7041
rdg:
7032
diff:
 -9

Right riser

A9
nom:
7238
rdg:
7220
diff:
-18
A10
nom:
7112
rdg:
7104
diff:
 -8
A11
nom:
7043
rdg:
7035
diff:
 -8
A12
nom:
6996
rdg:
6984
diff:
-12
A13
nom:
6976
rdg:
6967
diff:
 -9
A14
nom:
7018
rdg:
7007
diff:
-11
B12
nom:
7005
rdg:
6986
diff:
-19
B13
nom:
7013
rdg:
7000
diff:
-13
B14
nom:
7041
rdg:
7031
diff:
-10

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

No issues were found

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found

Buy us coffee