Review measurement
2024-02-12 17:19
Ozone Zeolite MS (2019)
In-group deviations
Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
Right riser
A15
nom:
6097
rdg:
6628
diff:
+6
A16
nom:
6044
rdg:
6571
diff:
+2
A17
nom:
6037
rdg:
6558
diff:
-4
B15
nom:
6120
rdg:
6652
diff:
+7
B16
nom:
6093
rdg:
6623
diff:
+5
B17
nom:
6080
rdg:
6604
diff:
-1
Trim
Groups arranged behind each other in flight direction having more than 10 mm deviation.
No issues were found
Group deviations
Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.
No issues were found