Review measurement

2026-04-11 11:06

Niviuk Icepeak X-One 24 (2020)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

a9
nom:
7611
rdg:
7602
diff:
 -9
a10
nom:
7524
rdg:
7515
diff:
 -9
a11
nom:
7466
rdg:
7458
diff:
 -8
a12
nom:
7479
rdg:
7469
diff:
-10
a13
nom:
7373
rdg:
7362
diff:
-11
a14
nom:
7363
rdg:
7345
diff:
-18
b9
nom:
7596
rdg:
7585
diff:
-11
c13
nom:
7382
rdg:
7367
diff:
-15
c14
nom:
7388
rdg:
7373
diff:
-15

Right riser

a9
nom:
7611
rdg:
7626
diff:
+15
a10
nom:
7524
rdg:
7523
diff:
 -1
a11
nom:
7466
rdg:
7467
diff:
 +1
a12
nom:
7479
rdg:
7476
diff:
 -3
a13
nom:
7373
rdg:
7370
diff:
 -3
a14
nom:
7363
rdg:
7364
diff:
 +1
b9
nom:
7596
rdg:
7599
diff:
 +3
c13
nom:
7382
rdg:
7378
diff:
 -4
c14
nom:
7388
rdg:
7386
diff:
 -2

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

No issues were found

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found