Review measurement

2026-06-10 20:46

Niviuk Koyot 4 26 (2019)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

c1
nom:
6845
rdg:
6872
diff:
+27
c2
nom:
6816
rdg:
6845
diff:
+29
d1
nom:
6965
rdg:
6983
diff:
+18
d2
nom:
6937
rdg:
6962
diff:
+25
a8
nom:
6352
rdg:
6377
diff:
+25
a9
nom:
6106
rdg:
6137
diff:
+31
b8
nom:
6301
rdg:
6328
diff:
+27
b9
nom:
6136
rdg:
6165
diff:
+29
c8
nom:
6206
rdg:
6234
diff:
+28

Right riser

c1
nom:
6845
rdg:
6870
diff:
+25
c2
nom:
6816
rdg:
6838
diff:
+22
d1
nom:
6965
rdg:
6990
diff:
+25
d2
nom:
6937
rdg:
6963
diff:
+26
a8
nom:
6352
rdg:
6369
diff:
+17
a9
nom:
6106
rdg:
6130
diff:
+24
b8
nom:
6301
rdg:
6323
diff:
+22
b9
nom:
6136
rdg:
6165
diff:
+29
c8
nom:
6206
rdg:
6228
diff:
+22

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

This should be corrected.

Left riser

nom:
6880.50
rdg:
6895.50
diff:
15.00
nom:
6770.00
rdg:
6795.50
diff:
25.50
nom:
6890.75
rdg:
6915.50
diff:
24.75

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median (22) of the deviations of all measurements from their nominal values.

No issues were found