Review measurement
2026-06-10 13:32
Ozone Zeno ML (2017)
In-group deviations
Readings that are more than 10
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
Right riser
A9
nom:
6786
rdg:
7284
diff:
-22
A10
nom:
6663
rdg:
7161
diff:
-22
A11
nom:
6602
rdg:
7096
diff:
-26
A12
nom:
6548
rdg:
7037
diff:
-31
A13
nom:
6531
rdg:
7021
diff:
-30
A14
nom:
6563
rdg:
7056
diff:
-27
B12
nom:
6556
rdg:
7045
diff:
-31
B13
nom:
6562
rdg:
7048
diff:
-34
B14
nom:
6587
rdg:
7078
diff:
-29
Trim
Groups arranged behind each other in flight direction having more than 10
This should be corrected.
Left riser
Right riser
nom:
7203.67
rdg:
7180.33
diff:
-23.33
nom:
7209.00
rdg:
7196.00
diff:
-13.00
Group deviations
Groups that are more than 20
The measurement baseline is the median (-15) of the deviations of all measurements from their nominal values.
No issues were found