Review measurement

2025-05-16 19:58

Ozone Zeno 2 ML (2022)

In-group deviations

Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

B5
nom:
7661
rdg:
7665
diff:
 +4
B6
nom:
7519
rdg:
7522
diff:
 +3
B7
nom:
7441
rdg:
7442
diff:
 +1
B8
nom:
7451
rdg:
7452
diff:
 +1
C5
nom:
7738
rdg:
7745
diff:
 +7
C6
nom:
7595
rdg:
7599
diff:
 +4
C7
nom:
7512
rdg:
7515
diff:
 +3
C8
nom:
7512
rdg:
7517
diff:
 +5

Right riser

B5
nom:
7661
rdg:
7662
diff:
 +1
B6
nom:
7519
rdg:
7520
diff:
 +1
B7
nom:
7441
rdg:
7434
diff:
 -7
B8
nom:
7451
rdg:
7444
diff:
 -7
C5
nom:
7738
rdg:
7743
diff:
 +5
C6
nom:
7595
rdg:
7597
diff:
 +2
C7
nom:
7512
rdg:
7507
diff:
 -5
C8
nom:
7512
rdg:
7512
diff:
 +0

Trim

Groups arranged behind each other in flight direction having more than 10 mm deviation.

No issues were found

Group deviations

Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found