Review measurement

2025-06-03 14:50

BGD Cure 2 S (2020)

Accuracy

Is calculated by comparing each suspension point's length change to the main line's overall change after re-measurement. Deviations over 3.0mm from the average are considered noticeable and may distort the trim result.

Left riser

Right riser

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

a1
nom:
7251
rdg:
7224
diff:
-27
a2
nom:
7174
rdg:
7153
diff:
-21
a3
nom:
7134
rdg:
7106
diff:
-28
a4
nom:
7166
rdg:
7134
diff:
-32

Right riser

a1
nom:
7251
rdg:
7232
diff:
-19
a2
nom:
7174
rdg:
7152
diff:
-22
a3
nom:
7134
rdg:
7105
diff:
-29
a4
nom:
7166
rdg:
7140
diff:
-26

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

No issues were found

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found