Review measurement

2025-07-01 16:17

Niviuk Icepeak X-One 26 (2020)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

a9
nom:
8170
rdg:
8164
diff:
 -6
a10
nom:
8077
rdg:
8072
diff:
 -5
a11
nom:
8015
rdg:
8006
diff:
 -9
a12
nom:
8029
rdg:
8024
diff:
 -5
a13
nom:
7910
rdg:
7907
diff:
 -3
a14
nom:
7899
rdg:
7892
diff:
 -7
b9
nom:
8154
rdg:
8152
diff:
 -2
c13
nom:
7918
rdg:
7919
diff:
 +1
c14
nom:
7925
rdg:
7927
diff:
 +2

Right riser

a9
nom:
8170
rdg:
8159
diff:
-11
a10
nom:
8077
rdg:
8064
diff:
-13
a11
nom:
8015
rdg:
8000
diff:
-15
a12
nom:
8029
rdg:
8017
diff:
-12
a13
nom:
7910
rdg:
7895
diff:
-15
a14
nom:
7899
rdg:
7888
diff:
-11
b9
nom:
8154
rdg:
8143
diff:
-11
c13
nom:
7918
rdg:
7907
diff:
-11
c14
nom:
7925
rdg:
7920
diff:
 -5

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

This should be corrected.

Left riser

Right riser

nom:
8869.88
rdg:
8868.88
diff:
-1.00
nom:
8917.13
rdg:
8905.50
diff:
-11.63

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median (-3) of the deviations of all measurements from their nominal values.

No issues were found