Review measurement

2025-07-01 18:43

Ozone Zeno 2 MS (2022)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A9
nom:
6992
rdg:
6982
diff:
-10
A10
nom:
6871
rdg:
6867
diff:
 -4
A11
nom:
6806
rdg:
6798
diff:
 -8
A12
nom:
6761
rdg:
6747
diff:
-14
A13
nom:
6742
rdg:
6725
diff:
-17
A14
nom:
6782
rdg:
6765
diff:
-17
B12
nom:
6769
rdg:
6751
diff:
-18
B13
nom:
6778
rdg:
6759
diff:
-19
B14
nom:
6805
rdg:
6784
diff:
-21

Right riser

A9
nom:
6992
rdg:
6983
diff:
 -9
A10
nom:
6871
rdg:
6867
diff:
 -4
A11
nom:
6806
rdg:
6801
diff:
 -5
A12
nom:
6761
rdg:
6747
diff:
-14
A13
nom:
6742
rdg:
6725
diff:
-17
A14
nom:
6782
rdg:
6761
diff:
-21
B12
nom:
6769
rdg:
6754
diff:
-15
B13
nom:
6778
rdg:
6764
diff:
-14
B14
nom:
6805
rdg:
6787
diff:
-18

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

This should be corrected.

Left riser

nom:
7552.63
rdg:
7551.75
diff:
-0.88
nom:
7561.63
rdg:
7549.50
diff:
-12.13

Right riser

nom:
7552.63
rdg:
7552.88
diff:
0.25
nom:
7561.63
rdg:
7546.50
diff:
-15.13
nom:
7285.50
rdg:
7283.63
diff:
-1.88
nom:
7295.88
rdg:
7283.25
diff:
-12.63

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found

Buy us coffee