Review measurement
2025-07-01 18:43
Ozone Zeno 2 MS (2022)
In-group deviations
Readings that are more than 10
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
Right riser
A9
nom:
6992
rdg:
6983
diff:
-9
A10
nom:
6871
rdg:
6867
diff:
-4
A11
nom:
6806
rdg:
6801
diff:
-5
A12
nom:
6761
rdg:
6747
diff:
-14
A13
nom:
6742
rdg:
6725
diff:
-17
A14
nom:
6782
rdg:
6761
diff:
-21
B12
nom:
6769
rdg:
6754
diff:
-15
B13
nom:
6778
rdg:
6764
diff:
-14
B14
nom:
6805
rdg:
6787
diff:
-18
Trim
Groups arranged behind each other in flight direction having more than 10
This should be corrected.
Left riser
nom:
7552.63
rdg:
7551.75
diff:
-0.88
nom:
7561.63
rdg:
7549.50
diff:
-12.13
Right riser
nom:
7552.63
rdg:
7552.88
diff:
0.25
nom:
7561.63
rdg:
7546.50
diff:
-15.13
nom:
7285.50
rdg:
7283.63
diff:
-1.88
nom:
7295.88
rdg:
7283.25
diff:
-12.63
Group deviations
Groups that are more than 20
The measurement baseline is the median of the deviations of all measurements from their nominal values.
No issues were found