Review measurement

2025-07-02 17:09

Ozone Zeolite GT ML (2019)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A15
nom:
6318
rdg:
6830
diff:
-13
A16
nom:
6264
rdg:
6771
diff:
-18
A17
nom:
6254
rdg:
6753
diff:
-26
B15
nom:
6342
rdg:
6853
diff:
-14
B16
nom:
6313
rdg:
6822
diff:
-16
B17
nom:
6298
rdg:
6797
diff:
-26

Right riser

A15
nom:
6318
rdg:
6830
diff:
-13
A16
nom:
6264
rdg:
6773
diff:
-16
A17
nom:
6254
rdg:
6759
diff:
-20
B15
nom:
6342
rdg:
6851
diff:
-16
B16
nom:
6313
rdg:
6821
diff:
-17
B17
nom:
6298
rdg:
6797
diff:
-26

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

This should be corrected.

Left riser

nom:
7151.33
rdg:
7132.33
diff:
-19.00
nom:
7155.50
rdg:
7148.33
diff:
-7.17

Right riser

nom:
7151.33
rdg:
7134.33
diff:
-17.00
nom:
7155.50
rdg:
7148.83
diff:
-6.67

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median (-10) of the deviations of all measurements from their nominal values.

No issues were found