Review measurement
2024-02-24 08:02
Ozone Zeno 2 L (2022)
In-group deviations
Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
Right riser
A1a
nom:
8295
rdg:
8280
diff:
-15
A2a
nom:
8181
rdg:
8169
diff:
-12
A3a
nom:
8140
rdg:
8126
diff:
-14
A4a
nom:
8176
rdg:
8157
diff:
-19
A1b
nom:
8281
rdg:
8265
diff:
-16
A2b
nom:
8166
rdg:
8151
diff:
-15
A3b
nom:
8126
rdg:
8100
diff:
-26
A4b
nom:
8164
rdg:
8141
diff:
-23
Trim
Groups arranged behind each other in flight direction having more than 10 mm deviation.
This should be corrected.
Left riser
nom:
8191.13
rdg:
8165.25
diff:
-25.88
nom:
8194.13
rdg:
8178.88
diff:
-15.25
Right riser
nom:
7899.88
rdg:
7880.00
diff:
-19.88
nom:
7903.75
rdg:
7894.13
diff:
-9.63
Group deviations
Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.
No issues were found