Review measurement

2024-12-28 06:37

Nova Ion 3 L (2015)

Accuracy

Is calculated by comparing each suspension point's length change to the main line's overall change after re-measurement. Deviations over 3.0mm from the average are considered noticeable and may distort the trim result.

Left riser

avg change:
25.00
std dev:
1.41
Ag1
dev:
+1.0
Ag2
dev:
-1.0
avg change:
21.50
std dev:
2.12
Ag3
dev:
+1.5
Ag4
dev:
-1.5
avg change:
8.67
std dev:
1.53
Ag5
dev:
+1.7
Ag6
dev:
-0.3
Ag7
dev:
-1.3
avg change:
7.83
std dev:
1.47
Ag8
dev:
-1.2
Sg1
dev:
-0.2
Bg8
dev:
+1.8
Sg2
dev:
-2.2
Sg3
dev:
+0.8
Sg4
dev:
+0.8
avg change:
22.50
std dev:
0.71
Bg1
dev:
-0.5
Bg2
dev:
+0.5
avg change:
5.00
std dev:
0.00
Bg3
dev:
0.0
Bg4
dev:
0.0
avg change:
4.33
std dev:
0.58
Bg5
dev:
+0.3
Bg6
dev:
+0.3
Bg7
dev:
-0.7
avg change:
9.50
std dev:
0.71
Cg1
dev:
+0.5
Cg2
dev:
-0.5
avg change:
9.50
std dev:
0.71
Cg3
dev:
-0.5
Cg4
dev:
+0.5
avg change:
9.00
std dev:
2.00
Cg5
dev:
-2.0
Cg6
dev:
0.0
Cg7
dev:
+2.0

Right riser

avg change:
24.50
std dev:
0.71
Ag1
dev:
+0.5
Ag2
dev:
-0.5
avg change:
23.50
std dev:
2.12
Ag3
dev:
+1.5
Ag4
dev:
-1.5
avg change:
11.67
std dev:
1.15
Ag5
dev:
-1.3
Ag6
dev:
+0.7
Ag7
dev:
+0.7
avg change:
8.17
std dev:
1.60
Ag8
dev:
-1.8
Sg1
dev:
+1.2
Bg8
dev:
+0.2
Sg2
dev:
+2.2
Sg3
dev:
+0.2
Sg4
dev:
-1.8
avg change:
8.50
std dev:
0.71
Bg1
dev:
-0.5
Bg2
dev:
+0.5
avg change:
7.50
std dev:
0.71
Bg3
dev:
-0.5
Bg4
dev:
+0.5
avg change:
3.67
std dev:
1.53
Bg5
dev:
-0.3
Bg6
dev:
+1.7
Bg7
dev:
-1.3
avg change:
9.50
std dev:
2.12
Cg1
dev:
-1.5
Cg2
dev:
+1.5
avg change:
7.00
std dev:
1.41
Cg3
dev:
+1.0
Cg4
dev:
-1.0
avg change:
10.00
std dev:
0.00
Cg5
dev:
0.0
Cg6
dev:
0.0
Cg7
dev:
0.0

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

No issues were found

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

No issues were found

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found

Buy us coffee