Review measurement
2024-08-15 15:13
Ozone Zeno 2 MS (2022)
In-group deviations
Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
Right riser
A9
nom:
6992
rdg:
6999
diff:
+7
A10
nom:
6871
rdg:
6885
diff:
+14
A11
nom:
6806
rdg:
6818
diff:
+12
A12
nom:
6761
rdg:
6774
diff:
+13
A13
nom:
6742
rdg:
6749
diff:
+7
A14
nom:
6782
rdg:
6785
diff:
+3
B12
nom:
6769
rdg:
6775
diff:
+6
B13
nom:
6778
rdg:
6789
diff:
+11
B14
nom:
6805
rdg:
6806
diff:
+1
Trim
Groups arranged behind each other in flight direction having more than 10 mm deviation.
This should be corrected.
Left riser
nom:
6889.67
rdg:
6901.33
diff:
+11.67
nom:
6913.33
rdg:
6913.67
diff:
+0.33
Group deviations
Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.
No issues were found