Review measurement
2025-03-20 14:08
Ozone Delta 4 MS (2020)
In-group deviations
Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
Right riser
B9
nom:
6910
rdg:
6898
diff:
-12
B10
nom:
6823
rdg:
6813
diff:
-10
B11
nom:
6820
rdg:
6811
diff:
-9
B12
nom:
6727
rdg:
6714
diff:
-13
B13
nom:
6718
rdg:
6709
diff:
-9
B14
nom:
6630
rdg:
6622
diff:
-8
B15
nom:
6632
rdg:
6623
diff:
-9
C13
nom:
6977
rdg:
6967
diff:
-10
C14
nom:
6887
rdg:
6876
diff:
-11
C15
nom:
6796
rdg:
6770
diff:
-26
C16
nom:
6778
rdg:
6770
diff:
-8
C17
nom:
6696
rdg:
6688
diff:
-8
C18
nom:
6688
rdg:
6680
diff:
-8
Trim
Groups arranged behind each other in flight direction having more than 10 mm deviation.
This should be corrected.
Left riser
nom:
6714.17
rdg:
6683.33
diff:
-30.83
nom:
6775.54
rdg:
6764.54
diff:
-11.00
Right riser
nom:
6714.17
rdg:
6686.33
diff:
-27.83
nom:
6775.54
rdg:
6764.69
diff:
-10.85
Group deviations
Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.
No issues were found