Review measurement
2026-01-12 19:24
Ozone Enzo 3 M (2017)
In-group deviations
Readings that are more than 10
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
Right riser
B1
nom:
8311
rdg:
8310
diff:
-1
B2
nom:
8261
rdg:
8261
diff:
+0
B3
nom:
8166
rdg:
8166
diff:
+0
B4
nom:
8162
rdg:
8160
diff:
-2
B5
nom:
8137
rdg:
8137
diff:
+0
B6
nom:
8128
rdg:
8129
diff:
+1
B7
nom:
8168
rdg:
8167
diff:
-1
B8
nom:
8195
rdg:
8193
diff:
-2
C1
nom:
8430
rdg:
8416
diff:
-14
C2
nom:
8382
rdg:
8373
diff:
-9
C3
nom:
8290
rdg:
8284
diff:
-6
C4
nom:
8284
rdg:
8279
diff:
-5
Trim
Groups arranged behind each other in flight direction having more than 10
This should be corrected.
Left riser
nom:
8218.13
rdg:
8206.63
diff:
-11.50
nom:
8191.00
rdg:
8192.63
diff:
1.63
nom:
7952.75
rdg:
7934.63
diff:
-18.13
nom:
7953.00
rdg:
7948.50
diff:
-4.50
Right riser
nom:
8218.13
rdg:
8207.25
diff:
-10.88
nom:
8191.00
rdg:
8190.38
diff:
-0.63
nom:
7952.75
rdg:
7936.63
diff:
-16.13
nom:
7953.00
rdg:
7950.13
diff:
-2.88
Group deviations
Groups that are more than 20
The measurement baseline is the median of the deviations of all measurements from their nominal values.
No issues were found