Review measurement

2026-03-30 02:36

BGD Cure 3 L (2025)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

a9
nom:
6967
rdg:
6946
diff:
-21
a10
nom:
6931
rdg:
6908
diff:
-23
a11
nom:
6857
rdg:
6841
diff:
-16
a12
nom:
6850
rdg:
6834
diff:
-16
a13
nom:
6781
rdg:
6762
diff:
-19
a14
nom:
6772
rdg:
6753
diff:
-19
a15
nom:
6712
rdg:
6699
diff:
-13
a16
nom:
6712
rdg:
6699
diff:
-13
c15
nom:
6764
rdg:
6757
diff:
 -7
c16
nom:
6812
rdg:
6803
diff:
 -9

Right riser

a9
nom:
6967
rdg:
6946
diff:
-21
a10
nom:
6931
rdg:
6909
diff:
-22
a11
nom:
6857
rdg:
6835
diff:
-22
a12
nom:
6850
rdg:
6831
diff:
-19
a13
nom:
6781
rdg:
6758
diff:
-23
a14
nom:
6772
rdg:
6750
diff:
-22
a15
nom:
6712
rdg:
6698
diff:
-14
a16
nom:
6712
rdg:
6698
diff:
-14
c15
nom:
6764
rdg:
6746
diff:
-18
c16
nom:
6812
rdg:
6800
diff:
-12

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

This should be corrected.

Left riser

nom:
7254.88
rdg:
7239.63
diff:
-15.25
nom:
7290.63
rdg:
7264.63
diff:
-26.00

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median (-23) of the deviations of all measurements from their nominal values.

No issues were found