Review measurement

2026-03-30 02:36

BGD Cure 3 L (2025)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

a9
nom:
6967
rdg:
6946
diff:
-21
a10
nom:
6931
rdg:
6908
diff:
-23
a11
nom:
6857
rdg:
6841
diff:
-16
a12
nom:
6850
rdg:
6834
diff:
-16
a13
nom:
6781
rdg:
6762
diff:
-19
a14
nom:
6772
rdg:
6753
diff:
-19
a15
nom:
6712
rdg:
6699
diff:
-13
a16
nom:
6712
rdg:
6699
diff:
-13
c15
nom:
6764
rdg:
6757
diff:
 -7
c16
nom:
6812
rdg:
6803
diff:
 -9

Right riser

a9
nom:
6967
rdg:
6946
diff:
-21
a10
nom:
6931
rdg:
6909
diff:
-22
a11
nom:
6857
rdg:
6835
diff:
-22
a12
nom:
6850
rdg:
6831
diff:
-19
a13
nom:
6781
rdg:
6758
diff:
-23
a14
nom:
6772
rdg:
6750
diff:
-22
a15
nom:
6712
rdg:
6698
diff:
-14
a16
nom:
6712
rdg:
6698
diff:
-14
c15
nom:
6764
rdg:
6746
diff:
-18
c16
nom:
6812
rdg:
6800
diff:
-12

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

This should be corrected.

Left riser

nom:
7254.88
rdg:
7239.63
diff:
-15.25
nom:
7290.63
rdg:
7264.63
diff:
-26.00

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found