Review measurement

2026-06-07 12:11

Ozone Rush 5 ML (2018)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

C9
nom:
6912
rdg:
6879
diff:
-33
C10
nom:
6842
rdg:
6812
diff:
-30
C11
nom:
6748
rdg:
6722
diff:
-26
C12
nom:
6752
rdg:
6721
diff:
-31
C13
nom:
6661
rdg:
6629
diff:
-32
C14
nom:
6648
rdg:
6616
diff:
-32

Right riser

C9
nom:
6912
rdg:
6886
diff:
-26
C10
nom:
6842
rdg:
6826
diff:
-16
C11
nom:
6748
rdg:
6735
diff:
-13
C12
nom:
6752
rdg:
6737
diff:
-15
C13
nom:
6661
rdg:
6638
diff:
-23
C14
nom:
6648
rdg:
6623
diff:
-25

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

This should be corrected.

Left riser

nom:
7040.00
rdg:
7032.75
diff:
-7.25
nom:
6973.75
rdg:
6952.50
diff:
-21.25
nom:
7081.63
rdg:
7070.88
diff:
-10.75

Right riser

nom:
7191.75
rdg:
7181.25
diff:
-10.50
nom:
7113.25
rdg:
7096.75
diff:
-16.50
nom:
7245.50
rdg:
7217.00
diff:
-28.50
nom:
6771.50
rdg:
6766.83
diff:
-4.67
nom:
6713.17
rdg:
6695.67
diff:
-17.50
nom:
6760.50
rdg:
6740.83
diff:
-19.67

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found