Review measurement
2025-04-19 10:27
Ozone Enzo 3 M (2017)
In-group deviations
Readings that are more than 10
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
Right riser
A5a
nom:
8099
rdg:
8098
diff:
-1
A6a
nom:
7952
rdg:
7946
diff:
-6
A7a
nom:
7881
rdg:
7876
diff:
-5
A8a
nom:
7909
rdg:
7900
diff:
-9
A5b
nom:
8082
rdg:
8083
diff:
+1
A6b
nom:
7936
rdg:
7932
diff:
-4
A7b
nom:
7866
rdg:
7863
diff:
-3
A8b
nom:
7897
rdg:
7887
diff:
-10
Trim
Groups arranged behind each other in flight direction having more than 10
This should be corrected.
Left riser
Right riser
nom:
8218.13
rdg:
8215.88
diff:
-2.25
nom:
8191.00
rdg:
8199.50
diff:
8.50
Group deviations
Groups that are more than 20
The measurement baseline is the median of the deviations of all measurements from their nominal values.
No issues were found