Review measurement

2025-08-26 23:12

Niviuk Peak 4 23 (2015)

Accuracy

Is calculated by comparing each suspension point's length change to the main line's overall change after re-measurement. Deviations over 3.0mm from the average are considered noticeable and may distort the trim result.

Left riser

avg change:
1.88
std dev:
1.55
a1
dev:
+2.9
a2
dev:
-0.1
a3
dev:
-0.1
a4
dev:
-1.1
b1
dev:
-1.1
b2
dev:
+0.9
b3
dev:
+0.9
b4
dev:
-2.1

Right riser

avg change:
3.50
std dev:
0.93
a5
dev:
-0.5
a6
dev:
+0.5
a7
dev:
-1.5
a8
dev:
-0.5
b5
dev:
+0.5
b6
dev:
-0.5
b7
dev:
+1.5
b8
dev:
+0.5

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

c5
nom:
6732
rdg:
7209
diff:
-13
c6
nom:
6618
rdg:
7101
diff:
 -7
c7
nom:
6589
rdg:
7075
diff:
 -4
c8
nom:
6666
rdg:
7153
diff:
 -3
d5
nom:
6870
rdg:
7346
diff:
-14
d6
nom:
6760
rdg:
7242
diff:
 -8
d7
nom:
6722
rdg:
7207
diff:
 -5
d8
nom:
6775
rdg:
7260
diff:
 -5

Right riser

c5
nom:
6732
rdg:
7211
diff:
-11
c6
nom:
6618
rdg:
7103
diff:
 -5
c7
nom:
6589
rdg:
7072
diff:
 -7
c8
nom:
6666
rdg:
7154
diff:
 -2
d5
nom:
6870
rdg:
7346
diff:
-14
d6
nom:
6760
rdg:
7241
diff:
 -9
d7
nom:
6722
rdg:
7204
diff:
 -8
d8
nom:
6775
rdg:
7260
diff:
 -5

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

No issues were found

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found

Buy us coffee